import esphome.codegen as cg from esphome.components import modbus, sensor import esphome.config_validation as cv from esphome.const import ( CONF_ACTIVE_POWER, CONF_APPARENT_POWER, CONF_CURRENT, CONF_EXPORT_ACTIVE_ENERGY, CONF_EXPORT_REACTIVE_ENERGY, CONF_FREQUENCY, CONF_ID, CONF_IMPORT_ACTIVE_ENERGY, CONF_IMPORT_REACTIVE_ENERGY, CONF_POWER_FACTOR, CONF_REACTIVE_POWER, CONF_VOLTAGE, DEVICE_CLASS_CURRENT, DEVICE_CLASS_ENERGY, DEVICE_CLASS_POWER, DEVICE_CLASS_POWER_FACTOR, DEVICE_CLASS_VOLTAGE, ICON_CURRENT_AC, STATE_CLASS_MEASUREMENT, STATE_CLASS_TOTAL_INCREASING, UNIT_AMPERE, UNIT_HERTZ, UNIT_VOLT, UNIT_VOLT_AMPS, UNIT_VOLT_AMPS_REACTIVE, UNIT_WATT, ) AUTO_LOAD = ["modbus"] CODEOWNERS = ["@sourabhjaiswal"] CONF_TOTAL_ACTIVE_ENERGY = "total_active_energy" CONF_TOTAL_REACTIVE_ENERGY = "total_reactive_energy" CONF_APPARENT_ENERGY = "apparent_energy" CONF_MAXIMUM_DEMAND_ACTIVE_POWER = "maximum_demand_active_power" CONF_MAXIMUM_DEMAND_REACTIVE_POWER = "maximum_demand_reactive_power" CONF_MAXIMUM_DEMAND_APPARENT_POWER = "maximum_demand_apparent_power" UNIT_KILOWATT_HOURS = "kWh" UNIT_KILOVOLT_AMPS_HOURS = "kVAh" UNIT_KILOVOLT_AMPS_REACTIVE_HOURS = "kVARh" selec_meter_ns = cg.esphome_ns.namespace("selec_meter") SelecMeter = selec_meter_ns.class_( "SelecMeter", cg.PollingComponent, modbus.ModbusDevice ) SENSORS = { CONF_TOTAL_ACTIVE_ENERGY: sensor.sensor_schema( unit_of_measurement=UNIT_KILOWATT_HOURS, accuracy_decimals=2, device_class=DEVICE_CLASS_ENERGY, state_class=STATE_CLASS_TOTAL_INCREASING, ), CONF_IMPORT_ACTIVE_ENERGY: sensor.sensor_schema( unit_of_measurement=UNIT_KILOWATT_HOURS, accuracy_decimals=2, device_class=DEVICE_CLASS_ENERGY, state_class=STATE_CLASS_TOTAL_INCREASING, ), CONF_EXPORT_ACTIVE_ENERGY: sensor.sensor_schema( unit_of_measurement=UNIT_KILOWATT_HOURS, accuracy_decimals=2, device_class=DEVICE_CLASS_ENERGY, state_class=STATE_CLASS_TOTAL_INCREASING, ), CONF_TOTAL_REACTIVE_ENERGY: sensor.sensor_schema( unit_of_measurement=UNIT_KILOVOLT_AMPS_REACTIVE_HOURS, accuracy_decimals=2, state_class=STATE_CLASS_TOTAL_INCREASING, ), CONF_IMPORT_REACTIVE_ENERGY: sensor.sensor_schema( unit_of_measurement=UNIT_KILOVOLT_AMPS_REACTIVE_HOURS, accuracy_decimals=2, state_class=STATE_CLASS_TOTAL_INCREASING, ), CONF_EXPORT_REACTIVE_ENERGY: sensor.sensor_schema( unit_of_measurement=UNIT_KILOVOLT_AMPS_REACTIVE_HOURS, accuracy_decimals=2, state_class=STATE_CLASS_TOTAL_INCREASING, ), CONF_APPARENT_ENERGY: sensor.sensor_schema( unit_of_measurement=UNIT_KILOVOLT_AMPS_HOURS, accuracy_decimals=2, state_class=STATE_CLASS_TOTAL_INCREASING, ), CONF_ACTIVE_POWER: sensor.sensor_schema( unit_of_measurement=UNIT_WATT, accuracy_decimals=3, device_class=DEVICE_CLASS_POWER, state_class=STATE_CLASS_MEASUREMENT, ), CONF_REACTIVE_POWER: sensor.sensor_schema( unit_of_measurement=UNIT_VOLT_AMPS_REACTIVE, accuracy_decimals=3, state_class=STATE_CLASS_MEASUREMENT, ), CONF_APPARENT_POWER: sensor.sensor_schema( unit_of_measurement=UNIT_VOLT_AMPS, accuracy_decimals=3, state_class=STATE_CLASS_MEASUREMENT, ), CONF_VOLTAGE: sensor.sensor_schema( unit_of_measurement=UNIT_VOLT, accuracy_decimals=2, device_class=DEVICE_CLASS_VOLTAGE, state_class=STATE_CLASS_MEASUREMENT, ), CONF_CURRENT: sensor.sensor_schema( unit_of_measurement=UNIT_AMPERE, accuracy_decimals=3, device_class=DEVICE_CLASS_CURRENT, state_class=STATE_CLASS_MEASUREMENT, ), CONF_POWER_FACTOR: sensor.sensor_schema( accuracy_decimals=3, device_class=DEVICE_CLASS_POWER_FACTOR, state_class=STATE_CLASS_MEASUREMENT, ), CONF_FREQUENCY: sensor.sensor_schema( unit_of_measurement=UNIT_HERTZ, icon=ICON_CURRENT_AC, accuracy_decimals=2, state_class=STATE_CLASS_MEASUREMENT, ), CONF_MAXIMUM_DEMAND_ACTIVE_POWER: sensor.sensor_schema( unit_of_measurement=UNIT_WATT, accuracy_decimals=3, device_class=DEVICE_CLASS_POWER, state_class=STATE_CLASS_MEASUREMENT, ), CONF_MAXIMUM_DEMAND_REACTIVE_POWER: sensor.sensor_schema( unit_of_measurement=UNIT_VOLT_AMPS_REACTIVE, accuracy_decimals=3, state_class=STATE_CLASS_MEASUREMENT, ), CONF_MAXIMUM_DEMAND_APPARENT_POWER: sensor.sensor_schema( unit_of_measurement=UNIT_VOLT_AMPS, accuracy_decimals=3, state_class=STATE_CLASS_MEASUREMENT, ), } CONFIG_SCHEMA = ( cv.Schema({cv.GenerateID(): cv.declare_id(SelecMeter)}) .extend( {cv.Optional(sensor_name): schema for sensor_name, schema in SENSORS.items()} ) .extend(cv.polling_component_schema("10s")) .extend(modbus.modbus_device_schema(0x01)) ) async def to_code(config): var = cg.new_Pvariable(config[CONF_ID]) await cg.register_component(var, config) await modbus.register_modbus_device(var, config) for name in SENSORS: if name in config: sens = await sensor.new_sensor(config[name]) cg.add(getattr(var, f"set_{name}_sensor")(sens))